产品中心
Product Center
—
DCD SR - 系列 - 信号/数据线的耦合/去耦网络
浪涌脉冲或环波脉冲通过独立的耦合/去耦网络应用于非屏蔽的非对称互连线(信号/数据线
)。对于此类测试,阿美特克CTS提供一系列DCD,用于4或8条信号/数据线。 根据 IEC/EN 61000-4-5 和 IEC/EN 61000-4-12,脉冲通过不同的耦合元件(如电容器或气体避雷器)耦合,具体取决于数据线信号的特性。
DCD SR - 系列 - 信号/数据线的耦合/去耦网络
浪涌脉冲或环波脉冲通过独立的耦合/去耦网络应用于非屏蔽的非对称互连线(信号/数据线
)。对于此类测试,阿美特克CTS提供一系列DCD,用于4或8条信号/数据线。 根据 IEC/EN 61000-4-5 和 IEC/EN 61000-4-12,脉冲通过不同的耦合元件(如电容器或气体避雷器)耦合,具体取决于数据线信号的特性。
> Coupling/decoupling networks according to
IEC/EN 61000-4-5 and IEC/EN 61000-4-12
> Interchangeable AE port protection modules
> Line voltage 50 V, 250 V (other on request)
> Test voltage up to 7 kV
> Models with automatic coupling
> EUT max. 600 VDC / 4 A
> Differential mode or Common mode coupling
SURGE APPLICATION
DCD SR - SERIES - MULTIFUNCTIONAL
COUPLING/DECOUPLING NETWORKS
The AMETEK CTS DCD sr - series of coupling decoupling networks are multifunctional CDNs for the application of
Surge and Ringwave pulses onto signal/data lines.
The standard DCD sr - models combine three different applications; coupling of Surge pulse via capacitor or gas
arrestor and coupling of Ring wave pulses via capacitor being required by the relevant standards. The required
coupling mode can easily be selected.
The surge coupling GTD (Gas Discharge Tube) is inside a simple jumper and can be changed depends the
application with an ABD plug (Avalanche Breaking Diode).There are also two plugs for using an individual external
coupling device.
The DCD sr series also has the required decoupling inductors (20 mH) for each line. To protect the measuring
system, an interchangeable, pluggable voltage protection module with overvoltage protection for 50 VDC is included
in the delivery at the signal/data line inputs on the AE port. Each module protects 4 lines, so that coupling
networks with 8 lines require two modules.
AMETEK CTS offers coupling networks for various voltage pulses up to 7 kV as well as for signal currents up to 4 A.
Various modules for 50 VDC and 250 VAC are available for pluggable voltage protection on the AE port. Protection
modules for signal voltages up to 600 VDC are available on request.
Dedicated CDNs are available e.g. for railway applications as per EN 50121 and for other customer specific test
applications.
COUPLING
MULTIFUNCTIONAL COUPLING FOR SURGE AND
RINGWAVE
The AMETEK DCD sr - series of coupling decoupling networks are multifunctional CDNs for the
application of Surge and Ringwave pulses onto signal/data lines.
Surge as per IEC 61000-4-5 Ed.3, Figure 9
- Capacitor 0.5 μF with 40 Ohm
- GDT gas arrestor with 40 Ohm
Ringwave as per IEC 61000-4-12 Ed.3, Figure 8
- Capacitor >= 3 μF
DCD SR SERIES FOR 4 UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES
5 KV MODELS, 4 LINES | |
DCD 5 sr-4-1 | 5 kV coupling/decoupling network max. line current 1 A |
DCD 5 sr-4-4 | 5 kV coupling/decoupling network line current 4 A, intermittent 5 A |
Line voltage | Depends on AE protection module max. 50 V / 250 V |
General data | |
Surge coupling | as per Fig. 9 IEC 61000-4-5 Ed.3, - 0.5 μF capacitor via 40 Ohm, - GDT gas arrestor via 40 Ohm |
Ringwave couplin | as per Fig. 8 IEC 61000-4-12 Ed.3, - capacitor >= 3 μF |
7 KV MODELS, 4 LINES | |
DCD 7 sr-4-1 | 7 kV coupling/decoupling network max. line current 1 A |
DCD 7 sr-4-4 | 7 kV coupling/decoupling network line current 4 A, intermittent 5 A |
Line voltage | Depends on AE protection module max. 50 V / 250 V |
General data | |
Surge coupling | as per Fig. 9 IEC 61000-4-5 Ed.3, - 0.5 μF capacitor via 40 Ohm, - GDT gas arrestor via 40 Ohm |
Ringwave couplin | as per Fig. 8 IEC 61000-4-12 Ed.3, - capacitor >= 3 μF |
AE PROTECTION MODULE | |
DPM 50-1 | 1 module with 4 lines included,the module can be plugged in manually. |
Diode Protection Module 50 V,bidirectional diodes, Impedance to GND: 1 kOhm | |
Line voltage | Vmax: 35 VAC, 50 VDC |
0ther models | other AE protection, see options |
ACCESSORIES FOR 5/7 KV DCD WITH 4 LINES | |
AE Protection | 1 x DPM 50-1 1 module with 4 lines, |
Coupling device | 1 x GDT, Gas discharge tube |
Short circuit bridges | 4 bridges,3 x long type, Art 109849, 1 x small type, Art 102783 |
HVS - Banana -Banana | HV cable 1.0 m for connection Generator - DCD 1 x red (HV) 1 x black (COM) |
Earth cable Art. 10945 | 1 x 0.6 m yellow-green 2 x M4 screws with toothed washer |
DCD SR SERIES FOR 8 UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES
5/7 KV MODELS, 8 LINES | |
DCD 5/7 sr-8-1 | 5/7 kV coupling/decoupling network max. line current 1 A |
DCD 5/7 sr-8-4 | 5/7 kV coupling/decoupling network line current 4 A, intermittent 5 A |
Line voltage | Depends on AE protection module max. 50 V / 250 V |
General data | |
Surge coupling | as per Fig. 9 IEC 61000-4-5 Ed.3, - 0.5 μF capacitor via 40 Ohm, - GDT gas arrestor via 40 Ohm |
Ringwave couplin | as per Fig. 8 IEC 61000-4-12 Ed.3, - capacitor >= 3 μF |
AE PROTECTION MODULE | |
DPM 50-1 | 1 module with 4 lines included,the module can be plugged in manually. |
Diode Protection Module 50 V,bidirectional diodes, Impedance to GND: 1 kOhm | |
Line voltage | Vmax: 35 VAC, 50 VDC |
0ther models | other AE protection, see options |
ACCESSORIES FOR 5/7 KV DCD WITH 8 LINES | |
AE Protection | 2 x DPM 50-1 2 module with 4 lines, |
Coupling device | 1 x GDT, Gas discharge tube |
Short circuit bridges | 4 bridges,3 x long type, Art 109849, 1 x small type, Art 102783 |
HVS - Banana -Banana | HV cable 1.0 m for connection Generator - DCD 1 x red (HV) 1 x black (COM) |
Earth cable Art. 10945 | 1 x 0.6 m yellow-green 2 x M4 screws with toothed washer |
OPTIONS
PROTECTION DEVICES | |
Protection unit | Module with 4 lines, the module can be plugged in manually. |
Required modules | DCD with 4 lines: 1 DCD with 8 lines: 2 |
VPM 250-100 | Varistor Protection Module 250 V, Varistor 250 VAC, 350 VDC, Impedance to GND: 100 kOhm |
DPM 50-1 | Diode Protection Module 50 V, bidirectional diodes, Vmax: 35 VAC, 50 VDC, Impedance to GND: 1 kOhm |
DPM 50 | Diode Protection Module 50 V, bidirectional diodes, Vmax: 35 VAC, 50 VDC, Impedance to GND: Open circuit |
Other | Other protection units on request |
COUPLING DEVICES | |
GDT | Gas Discharge Tube Coupling via 90 V gas arrestor for Surge 1,2/50 μs and Ring wave 0.5 μs, 100 kHz Max. Impulse voltage 7 kV |
ABD Plug | Avalanche Breaking Diode Coupling 140 V diode for Surge 1,2/50 μs and Ring wave 0.5 μs, 100 kHz Max. Impulse voltage 7 kV |
GENERAL
DECOUPLING | |
Decoupling inductance | 20 mH, each line |
ENVIRONMENT | |
Temperature | 10 °C to 40 °C |
Humidity | 10 % to 80 %, non condensing |
Atmospheric pressur | 86 kPa (860 mbar) to 106 kPa (1,060 mbar) |
DIMENSION AND WEIGHTS | |
Model | dimension (W x D x H), weight |
DCD 5 sr-4-1 | 19" 3 HU, 447 x 500 x 143 mm, approx. 10 kg |
DCD 5 sr-4-4 | 19" 3 HU, 447 x 500 x 143 mm, approx. 12 kg |
DCD 5 sr-8-1 | 19" 3 HU, 447 x 500 x 143 mm, approx. 12 kg |
DCD 5 sr-8-4 | 19" 3 HU, 447 x 500 x 143 mm, approx. 18 kg |
DCD 7 sr-4-1 | 19" 6 HU, 447 x 500 x 286 mm, approx. 14 kg |
DCD 7 sr-4-4 | 19" 6 HU, 447 x 500 x 286 mm, approx. 14 kg |
DCD 7 sr-8-1 | 19" 6 HU, 447 x 500 x 286 mm, approx. 18 k |
DCD 7 sr-8-4 | 19" 6 HU, 447 x 500 x 286 mm, approx. 18 k |
DCD MODELS WITH AUTOMATIC COUPLING
DCD 5-A MODELS FOR UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES | |
DCD 5-A-sr-8-4 | 5 kV coupling/decoupling network,8 unshielded unsymmetrical signal lines for Surge and Ring wave,Automatic coupling, Coupling : - 40 Ohm/ 0.5 μF, - 40 Ohm/ TVS element, - 500 Ohm/ 0.5 μF, EUT max. 600 V peak 4 A,limitted by AE port protection |
DCD 5-A-b-8-4 | 5 kV coupling/decoupling network,8 unshielded unsymmetrical signal lines for EFT / Burst,Automatic coupling,EUT max. 300 VAC / 420 VDC, 4A,limitted by AE port protection |
电磁兼容测试